Configuration error messages
A list of configuration error messages. For messages that are not self-explanatory, additional information is provided.
Number | Description |
---|---|
GS-19001 | Unable to send data to a non connected remote
task. Internal error. |
GS-19002 | Remote server unavailable. Cannot connect to the remote host. |
GS-19004 | Remote processing error. Internal error. |
GS-19005 | Incompatible server protocol. The protocol versions in the client and the server are not the same. See Remote environment software requirements. |
GS-19006 | A server is listening on the given port, but it isn't
a Studio Server. Error message and resolution should be self-explanatory. |
GS-19007 | Studio Server is listening on the given port, but it
doesn't use the same protocol version.
Error message and resolution should be self-explanatory. |
GS-19008 | Disconnection has been forced by the client. Error message and resolution should be self-explanatory. |
GS-19009 | The server disconnected. Error message and resolution should be self-explanatory. |
GS-19010 | Internal socket error.
Internal error. |
GS-19011 | Request aborted.
Internal error. |
GS-19012 | Server is not reachable or doesn't listen on given
port. Error message and resolution should be self-explanatory. |
GS-19013 | Connected to %1.
Error message and resolution should be self-explanatory. |
GS-19100 | Host address and port pair must be unique: %1 host
configuration has same host (%2) and port (%3)" Error message and resolution should be self-explanatory. |
GS-19101 | Connecting to '%1' |
GS-19102 | Connection failed: cannot connect to the Genero Studio Server Error message and resolution should be self-explanatory. |
GS-19103 | Connection failed: the Genero Studio Server uses a different protocol
version The versions of Genero Studio and Genero Studio Server do not match. See Remote environment software requirements. |
GS-19104 | Client IP address has been converted from IPv6 to
IPv4. Client IP address has been converted from IPv6 to IPv4.
Client IP address is invalid. FGL runner may not manage to
connect to GUI. Error message and resolution should be self-explanatory. |
GS-19105 | No mount point defined
Error message and resolution should be self-explanatory. |
GS-19111 | Cannot write temporary file '%1 Error message and resolution should be self-explanatory. |
GS-19200 | Path cannot be empty Error message and resolution should be self-explanatory. |
GS-19201 | FGL runner cannot be empty Error message and resolution should be self-explanatory. |
GS-19202 | Testing '%1' Error message and resolution should be self-explanatory. |
GS-19300 | <Choose a Genero Install> Informational message. |
GS-19301 | <Choose a Display Client> Informational message. |
GS-19302 | <Choose an Application Server
Configuration> Informational message. |
GS-19303 | Fetching infos from GAS... Informational message. |
GS-19304 | GAS has refused to give informations. Verify your GAS
settings Failed to start GAS. This message will only be seen for GAS versions >= 2.40. Starting with 2.40, once the GAS version number is retrieved, Genero Studio tries to get the information about the application groups. This message appears when the retrieval of the GAS version number is successful, yet the retrieval of the application group information is not successful. To remedy the issue, verify that the GAS is started, and that the host and port values are correct. The GAS should also be configured to allow Genero Studio access to the GAS monitor. By default, the GAS monitor can only be accessed from the localhost, and Genero Studio/gsserver must be on the same machine as the GAS to access it. |
GS-19400 | Path cannot be empty Error message and resolution should be self-explanatory. |
GS-19401 | Host IP address cannot be empty Error message and resolution should be self-explanatory. |
GS-19402 | Display client will not be accessible from other
machines Error message and resolution should be self-explanatory. |
GS-19500 | Application group directory cannot be empty Error message and resolution should be self-explanatory. |
GS-19501 | Parent application cannot be empty Error message and resolution should be self-explanatory. |
GS-19502 | Application group cannot be empty Error message and resolution should be self-explanatory. |
GS-19503 | Start script path cannot be empty Error message and resolution should be self-explanatory. |
GS-19504 | Connector cannot contain only blanks Error message and resolution should be self-explanatory. |
GS-19505 | Web service group directory cannot be empty Error message and resolution should be self-explanatory. |
GS-19506 | Parent web service cannot be empty
Error message and resolution should be self-explanatory. |
GS-19507 | Web service group cannot be empty
Error message and resolution should be self-explanatory. |
GS-19600 | Incorrect environment variable '%1' value Error message and resolution should be self-explanatory. |
GS-19601 | Put one and only one Genero Mobile for Android
package in $(GMADIR) Error message and resolution should be self-explanatory. |
GS-19602 | Display Client type should be 'iOS' or 'iOS
Simulator' Error message and resolution should be self-explanatory. |
GS-19603 | Debug server connection error, check if the mobile
app is running on the device
Error message and resolution should be self-explanatory. |
GS-19604 | Starting display client...
Informational message. |