Numeric data types
Informix®
Informix supports several data types to store numbers:
Informix data type | Description |
---|---|
SMALLINT |
16 bit signed integer |
INTEGER |
32 bit signed integer |
BIGINT |
64 bit signed integer |
INT8 |
64 bit signed integer (replaced by
BIGINT ) |
DECIMAL |
Equivalent to DECIMAL(16) |
DECIMAL(p) |
Floating-point decimal number (max precision is 32) |
DECIMAL(p,s) |
Fixed-point decimal number (max precision is 32) |
MONEY |
Equivalent to DECIMAL(16,2) |
MONEY(p) |
Equivalent to DECIMAL(p,2) (max precision is
32) |
MONEY(p,s) |
Equivalent to DECIMAL(p,s) (max precision is
32) |
REAL / SMALLFLOAT |
32-bit floating point decimal (C float) |
DOUBLE PRECISION / FLOAT[(n)] |
64-bit floating point decimal (C double) |
Dameng®
Dameng supports the following numeric data types:
Dameng data type | Description |
---|---|
SMALLINT |
16 bit signed integer |
INTEGER |
32 bit signed integer |
BIGINT |
64 bit signed integer |
DECIMAL(p,s) |
Fixed point decimal (max is 38 digits) |
DECIMAL |
Floating point decimal |
REAL |
32-bit floating point decimal (C float) |
DOUBLE |
64-bit floating point decimal (C double) |
Solution
Use the following conversion rules to map Informix numeric types to Dameng numeric types:
Informix data type | Dameng equivalent |
---|---|
SMALLINT |
SMALLINT |
INTEGER |
INTEGER |
INT8 / BIGINT |
BIGINT |
DECIMAL(p,s) |
DECIMAL(p,s) |
DECIMAL[(p)] |
DECIMAL (floating point decimal) |
MONEY |
DECIMAL(16,2) |
MONEY(p) |
DECIMAL(p,2) |
MONEY(p,s) |
DECIMAL(p,s) |
SMALLFLOAT |
REAL |
FLOAT[(n)] |
DOUBLE |
SQL scripts to create databases must be converted manually. Tables created from BDL programs do
not have to be converted; the database interface detects the MONEY
data type and
uses the DECIMAL
type for Dameng.
Note:
Avoid using DECIMAL
type in FGL or SQL: Due to the implementation
differences in Informix SQL / Genero BDL and the native SQL type, such data type is not recommended.
Always specify a precision and scale with [
(p)]
DECIMAL(p,s)
.
The numeric types translation can be
controlled with the following FGLPROFILE
entries:
dbi.database.dsname.ifxemul.datatype.smallint = {
true |
false }
dbi.database.dsname.ifxemul.datatype.integer = {
true |
false }
dbi.database.dsname.ifxemul.datatype.bigint = {
true |
false }
dbi.database.dsname.ifxemul.datatype.int8 = {
true |
false }
dbi.database.dsname.ifxemul.datatype.decimal = {
true |
false }
dbi.database.dsname.ifxemul.datatype.money = {
true |
false }
dbi.database.dsname.ifxemul.datatype.float = {
true |
false }
dbi.database.dsname.ifxemul.datatype.smallfloat = {
true |
false }
For more details see IBM Informix emulation parameters in FGLPROFILE.