ACCEPT INPUT instruction
Syntax
ACCEPT INPUT
Usage
The ACCEPT INPUT
instruction validates and exits the INPUT
instruction, if no error is raised.
The AFTER FIELD
, ON CHANGE
, etc. control blocks will be
executed.
The statements after the ACCEPT INPUT
instruction will be skipped.
INPUT BY NAME cust_rec.*
...
ON ACTION process_order
CALL set_missing_defaults()
ACCEPT INPUT
...
END INPUT
The INPUT
instruction creates the default accept action to let the user validate
the dialog. Use of the ACCEPT INPUT
instruction is recommended only in specific
cases when the default accept action is not appropriated.
The ACCEPT INPUT
instruction can only be used in a singular
INPUT
dialog, it cannot be used in a DIALOG / END DIALOG
multiple