User interruption handling
Allow the end user to cancel a dialog or a long running procedure.
Basics
- The Unix "interrupt signal" (SIGINT): Can be triggered by a kill -s INT
command, or by a
CTRL-C
key in a terminal (see stty -a)). To detect theCTRL-C
key on Microsoft Windows platforms, the concept is a bit different and managed by Console Control Handlers. Note that a Unix SIGINT signal can occur in TUI or GUI mode. - The Unix "quit signal" (SIGQUIT): Can be triggered by a kill -s QUIT command,
or by a
CTRL-\
key in a terminal (see stty -a)). Like SIGINT, a SIGQUIT signal can occur in TUI or GUI mode on Unix. - The 'cancel' (and 'close') predefined actions of singular dialogs, when the runtime system is waiting for a user action.
- The asynchronous user interruption event, fired by a action view (button) with the name 'interrupt', when the runtime system is in processing mode (FOR loop, SQL query)
If the program executes an interactive instruction, the GUI front-end can send action events
triggered by the user such as 'accept' and 'cancel'. But when the program performs a long process
like a loop, a report, or a database query, the front-end has no control. In the second case, user
interruption can be detected by using the int_flag
register and the 'interrupt' action name.
Tips for SIGINT and SIGQUIT signals
Typical Genero programs should use DEFER
INTERRUPT
and DEFER QUIT
, otherwise any SIGINT or SIGQUIT signal
will just stop the process.
Sending a SIGINT when a program is in a SLEEP will cancel the sleep, because this is a system call that is interruptible.
In GUI mode, one can still send SIGINT signals to the fglrun process, but that's not good practice and will not stop the current dialog as in TUI mode.
Detecting dialog cancellation
When executing a singular dialogs such as
INPUT BY NAME
, the runtime system creates automatically the 'accept' and 'cancel'
predefined actions, to let the user
validate or reject the dialog. When executing a multiple dialog, there is no predefined 'cancel'
action created, and int_flag
is not set, even for user-defined ON ACTION
cancel
handlers.
With singular dialogs, the int_flag
register is typically tested after the dialog block (or in the
AFTER INPUT
block for example), to detect if the user wants the dialog input to be
validated or rejected. Note that int_flag
is not reset to FALSE
when the automatic 'accept' action is fired. Therefore, it is good practice to initialize
int_flag
to FALSE
, before starting a singular dialog.
In TUI mode, to cancel a singular dialog, user presses the CTRL-C
key in the
terminal, which produces a SIGINT signal and leaves the dialog instruction, after setting
int_flag
to 1/TRUE
. Since the trigger to cancel a singular dialog
in TUI mode is the SIGINT signal, the dialog can also be canceled by sending the SIGINT signal to
the fglrun
process. This is however not good practice. Dialog cancellation with
SIGINT is supported for legacy TUI applications.
In GUI mode, to cancel a singular dialog, user fires the 'cancel' (or 'close') predefined action,
to leave the dialog instruction, and int_flag
is set to 1/TRUE
.
There is no interrupt signal or interrupt event used in this case: This is triggered by a regular
GUI action event.
Detecting asynchronous user interruptions
BUTTON sb: interrupt, TEXT="Stop";
When the runtime system takes control to process program code or execute a long running SQL query, the front-end automatically enables the local 'interrupt' action to let the user send an asynchronous interruption request to the program.
A program (the runtime system) can also receive a SIGINT interruption signal from the operating system. The interruption request that comes from the front-end is a different source. However, the runtime system handles both type of interruption events the same way.
When receiving an interrupt event from the front-end (from the particular 'interrupt' action), or
from the system (SIGINT) the runtime system sets the int_flag
register to TRUE
.
DEFER INTERRUPT
and
test the int_flag
register to properly handle user interruptions, and avoid
immediate program termination. If the DEFER INTERRUPT
instruction is not used, the
program will stop immediately when an interruption event is caught. With DEFER
INTERRUPT
, the program continues, and can test int_flag
to check if an
interruption event occurred. It is good practice to reset int_flag
to
FALSE
after detecting interruption:WHILE ...
IF int_flag THEN
LET int_flag=FALSE
ERROR "Procedure was interrupted by the user"
EXIT WHILE
END IF
...
END WHILE
SQL queries can be interrupted too, if the target database supports this feature and the
OPTIONS SQL INTERRUPT ON
instruction is used. However, since the control is on the
database server side while the SQL statement is running, it is not possible to execute program code
to check int_flag
. In order to detect an SQL interruption, check the sqlca.sqlcode
register after the query for SQL error -213, indicating that the last SQL statement was
interrupted.
It is good practice to surround the SQL statement with OPTIONS
SQL INTERRUPT ON/OFF
and WHENEVER ERROR CONTINUE/STOP
(or a
TRY/CATCH
block): You don't want other SQL statements to be interruptible, and if
they fail but should not (for example if the table does not exist), the program must
stop.
OPTIONS SQL INTERRUPT ON
WHENEVER ERROR CONTINUE
SELECT COUNT(*) INTO cnt FROM ... -- Long running SQL statement
WHENEVER ERROR STOP
OPTIONS SQL INTERRUPT OFF
IF sqlca.sqlcode == -213 THEN
ERROR "Database query interrupted by user"
...
END IF
When not using DEFER INTERRUPT
, if the program enters in a long running
procedure, a button with the action name 'interrupt' will become active. The user can then
press that button, and the runtime system will stop the program, since DEFER
INTERRUPT
is not used. However, this will not happen when a dialog is active,
because the 'interrupt' button will be automatically disabled in that context. Such
situation can confuse the end user, expecting that the 'interrupt' button can stop the
program in any context.
Note that the front-end can not handle interruption requests properly, if the application code
generates a lot of AUI traffic, by doing many ui.Interface.refresh()
calls. This refresh method should not be called more
often than once in one second.
Implementing interruption of a long running SQL query
-- db_busy.per
LAYOUT
GRID
{
Database query in progress...
[sb ]
}
END
END
ATTRIBUTES
BUTTON sb: interrupt, TEXT="Stop";
END
MAIN
DEFINE oc INT
DEFER INTERRUPT
DATABASE stores
OPEN FORM f FROM "db_busy"
DISPLAY FORM f
CALL ui.Interface.refresh()
OPTIONS SQL INTERRUPT ON
WHENEVER ERROR CONTINUE
SELECT COUNT(*) INTO oc FROM orders
WHENEVER ERROR STOP
OPTIONS SQL INTERRUPT OFF
IF sqlca.sqlcode == -213 THEN
ERROR "Database query has been interrupted..."
END IF