NEXT FIELD instruction
Syntax
NEXT FIELD
{
CURRENT
|
NEXT
|
PREVIOUS
|
field-spec
}
- field-name: The name of the field as defined in the form file.
- table-name.field-name: The name of SQL table and field name as defined in the form file.
- screen-record-name.field-name: The screen record name and field name as defined in the form file.
FORMONLY.field-name
: TheFORMONLY
keyword followed by the field name as defined in the form file.
Purpose of NEXT FIELD instruction
The NEXT FIELD field-name
instruction gives the focus to the specified
field. This instruction can be used to control field input, in BEFORE FIELD
, ON CHANGE
or AFTER FIELD
blocks, it can also force a
DISPLAY ARRAY
or INPUT ARRAY
to stay in the current row when
NEXT FIELD
is used in the AFTER
ROW
block.
If it exists, the BEFORE FIELD
block of the destination field is executed.
However, in the context of a singular dialog, or when in a DIALOG
block and the
next field is in the same sub-dialog as the current field, the AFTER FIELD
of the
current field is not executed.
In INPUT
, INPUT ARRAY
and CONSTRUCT
dialogs,
the purpose of the NEXT FIELD
instruction is to give the focus to an focusable
field. Make sure that the field specified in NEXT FIELD
is active and focusable, or
use NEXT FIELD CURRENT
.
In a DISPLAY ARRAY
using the FOCUSONFIELD
attribute, NEXT FIELD
can be used in
conjunction with DIALOG.setCurrentRow()
, to set the focus to a specific cell in the list.
Instead of the NEXT FIELD
instruction, you can use the DIALOG.nextField("field-name")
method to register a field, for
example when the name is not known at compile time. However, this method only registers the field.
It does not stop code execution, like the NEXT FIELD
instruction does. You must
execute a CONTINUE DIALOG
to get the same behavior as NEXT
FIELD
.
Form field identification with NEXT FIELD
With the NEXT FIELD
instruction, fields are identified by the form field name specification, not the program
variable name used by the dialog.
Abstract field identification is also supported with the CURRENT
,
NEXT
and PREVIOUS
keywords.
Form fields are bound to program
variables with the binding clause of the dialog instruction (INPUT
variable-list FROM field-list
, INPUT BY NAME
variable-list
, CONSTRUCT BY NAME sql ON
column-list
, CONSTRUCT sql ON
column-list FROM field-list
, INPUT ARRAY
array-name FROM screen-array.*
).
The field name specification can be any of the following:
- field-name
- table-name.field-name
- screen-record-name.field-name
FORMONLY.field-name
Here are some examples:
cust_name
customer.cust_name
cust_screen_record.cust_name
item_screen_array.item_label
formonly.total
When no field name prefix is used, the first form field matching that simple field name is used.
When using a prefix in the field name specification, it must match the field prefix
assigned by the dialog field binding method used at the beginning of the interactive statement: When
no screen-record has been explicitly specified in the field binding clause (for example, when using
INPUT BY NAME variable-list
), the field prefix must be
the database table name or FORMONLY
, as defined in the form file, or any valid screen-record using
that field. When the FROM
clause of the dialog specifies an explicit screen-record
(for example, in INPUT variable-list FROM screen-record.* /
field-list-with-screen-record-prefix
or INPUT ARRAY
array-name FROM screen-array.*
), the field
prefix must be the screen-record name used in the FROM
clause.
Abstract field identification is supported with the CURRENT
,
NEXT
and PREVIOUS
keywords. NEXT FIELD CURRENT
forces to stay in the current field; NEXT FIELD NEXT
selects the field right after
the current field; NEXT FIELD PREVIOUS
selects the field right before the current
field. When using FIELD ORDER FORM
, the NEXT
and
PREVIOUS
options follow the tabbing order defined by the form. Otherwise, they
follow the order defined by the input binding list (with the FROM
or BY
NAME
clause). The field selected with NEXT
or PREVIOUS
keywords may be non-focusable.
NEXT FIELD PREVIOUS
and NEXT FIELD NEXT
is
discouraged: The target field may be non-focusable (it can be enabled/disabled during dialog
execution). Dependending on the context, the field selection can be based on the last field
navigation direction, and can lead to infinite loops. Always use NEXT FIELD CURRENT
or NEXT FIELD field-name
of a field that is focusable.NEXT FIELD to a non-focusable field
- Fields defined with the
NOENTRY
attribute in the form. - Fields defined as
PHANTOM
fields in the form. - Fields disabled at runtime with
DIALOG.setFieldActive("field-spec",FALSE)
. - Fields using a widget that does not allow input, such as a
LABEL
.
NEXT FIELD field-name
may explicitly specify a non-focusable
field. A non-focusable field can also be the target, when NEXT FIELD NEXT
or
NEXT FIELD PREVIOUS
selects a non-focusable field, based on the current tabbing order.
NEXT FIELD
to a non-focusable field can lead to
infinite loops in the dialog; This practice is discouraged. To stay in the current field / row, use
NEXT FIELD CURRENT
instead.NEXT FIELD in procedural DIALOG blocks
In a procedural dialog block, the
NEXT FIELD field-name
instruction gives the focus to the specified field
controlled by INPUT
, INPUT ARRAY
or CONSTRUCT
, or
to a read-only list when using DISPLAY ARRAY
.
When using a DISPLAY ARRAY
sub-dialog, it is possible to give the focus to the
list, by specifying the name of the first column as argument for NEXT FIELD
.
If the target field specified in the NEXT FIELD
instruction is inside the
current sub-dialog, neither AFTER FIELD
nor AFTER ROW
will be invoked for the field
or list you are leaving. However, the BEFORE FIELD
control blocks of the
destination field (or the BEFORE
ROW
in case of read-only list) will be executed.
If the target field specified in the NEXT FIELD
instruction is outside
the current sub-dialog, the AFTER FIELD
, AFTER INSERT
, AFTER
ROW
, and AFTER INPUT
, AFTER DISPLAY
, AFTER
/CONSTRUCT
control blocks will be invoked for the field or list you are leaving. Form-level validation rules will also be
checked, as if the user had selected the new sub-dialog himself. This guarantees the current
sub-dialog is left in a consistent state. The BEFORE INPUT
, BEFORE
DISPLAY
, BEFORE CONSTRUCT
, BEFORE ROW
and the
BEFORE FIELD
control blocks of the destination field / list will then be
executed.
NEXT FIELD in record list control blocks
When using NEXT FIELD
in AFTER
ROW
or in ON ROW
CHANGE
of a DISPLAY ARRAY
or INPUT ARRAY
, the
dialog will stay in the current row and give control back to the user.
This behavior allows you to implement data input rules:
AFTER ROW
IF NOT int_flag AND arr_count()<=arr_curr() THEN
IF arr[arr_curr()].it_count * arr[arr_curr()].it_value > maxval THEN
ERROR "Amount of line exceeds max value."
NEXT FIELD item_count
END IF
END IF
If a condition is not met for a given field, do a NEXT FIELD
to that field to
point the user to the problem. If a global condition for the current row is not met, use
NEXT FIELD CURRENT
to stay in the current row and current field.
NEXT FIELD in DISPLAY ARRAY with FOCUSONFIELD
DISPLAY ARRAY
dialogs support cell-oriented navigation with the FOCUSONFIELD
dialog attribute.
The NEXT FIELD
instruction can be used in DISPLAY ARRAY
with
FOCUSONFIELD
, to give the focus to a specific field in the current row.
NEXT FIELD
can be combined with DIALOG.setCurrentRow()
, to give the focus to a specific cell in the
table.