DISPLAY BY NAME
The DISPLAY BY NAME instruction displays
data to form fields explicitly by name.
Syntax
DISPLAY BY NAME { variable | record.* } [,...]
[ ATTRIBUTES ( display-attribute [,...] ) ]
where display-attribute is:
{ BLACK | BLUE | CYAN | GREEN
| MAGENTA | RED | WHITE | YELLOW
| BOLD | DIM | NORMAL
| REVERSE | BLINK | UNDERLINE
}
- variable is a program variable that has the same name as a form field.
- record.* is a record variable that has members with the same names as form fields.
Usage
A DISPLAY BY NAME statement
copies the data from program variables to the form fields
associated to the variables by name. The program variables
used in DISPLAY BY NAME must have the same name as
the form fields where they have to be displayed. The language
ignores any record structure name prefix when matching the
names. The names must be unique and unambiguous; if not, the
instruction raises an error.
company and
address1):DISPLAY BY NAME p_customer.cust_company,
p_customer.cust_address1The DISPLAY
BY NAME instruction is usually not needed if the program
is always in the context of a dialog controlling the form
fields.
DISPLAY BY NAME uses the default screen record
DISPLAY TO instruction where you can explicitly specify a screen record or screen array, DISPLAY
BY NAME displays data to the screen fields of the default screen records. The default
screen records are those having the names of the tables defined in the TABLES
section of the form specification file. When the form fields define a record list in the layout,
only the first row can be referenced with the default screen record. In the next example, the form
contains a static record list definition in the
layout.SCHEMA mystock
SCREEN
{
[f01 |f02 |f03 ]
[f01 |f02 |f03 ]
[f01 |f02 |f03 ]
[f01 |f02 |f03 ]
}
END
TABLES
customer
END
ATTRIBUTES
f01 = customer.cust_key;
f02 = customer.cust_name;
f03 = customer.cust_address;
ENDIn the program, a DISPLAY BY
NAME statement will display the data in the first
line of the record list in the form:
DISPLAY BY NAME record_cust.*
DISPLAY TO / BY NAME changes the touched flag
The DISPLAY TO / BY NAME statement changes the modification flag of the target fields. After
displaying a field value with a DISPLAY TO / BY NAME instruction, the FIELD_TOUCHED() operator returns true and
the ON CHANGE and ON ROW CHANGE triggers may be
invoked, if the current field value was changed.
In dialogs controlling field input such as INPUT or INPUT
ARRAY, use the UNBUFFERED attribute to display data to fields automatically without changing the
'touched' status of fields. The UNBUFFERED clause will perform automatic form field
and program variable synchronization. When using the UNBUFFERED mode, the touched
flag can be set with DIALOG.setFieldTouched(), if you want to get the same effect
as a DISPLAY TO / BY NAME.
Specifying TTY attributes in the DISPLAY statements
The ATTRIBUTES clause temporarily overrides any default display attributes or
any attributes specified in the OPTIONS or OPEN WINDOW statements
for the fields. When the DISPLAY TO / BY NAME statement completes execution, the
default display attributes are restored. In a DISPLAY TO / BY NAME statement, any
screen attributes specified in the ATTRIBUTES clause apply to all the fields that
you specify after the TO keyword.
The REVERSE, BLINK, INVISIBLE, and
UNDERLINE attributes are not sensitive to the color or monochrome status of the
terminal, if the terminal is capable of displaying these intensity modes. The
ATTRIBUTES clause can include zero or more of the BLINK,
REVERSE, and UNDERLINE attributes, and zero or one of the other
attributes. That is, all of the attributes except BLINK, REVERSE,
and UNDERLINE are mutually exclusive.
The DISPLAY TO / BY NAME statement ignores the INVISIBLE
attribute, regardless of whether you specify it in the ATTRIBUTES clause.