Running mobile apps on an application server
From the mobile device, programs can be started remotely on an application server, and displayed on the device.
Purpose of remote application execution for mobile devices
Remote applications displayed on a mobile device allow the use of the processor, memory, storage and software resources available on a server, for mobile users.
Executing remote/server applications for display on a mobile device requires a reliable and constant network connection. If the network connection fails, the application will stop, as with other client/server Genero front-ends.
Server applications can only be started through the Genero Application Server (GAS), by using the UA protocol available since version 3.00. You must set up and configure the GAS for the programs you want to start remotely. See the GAS documentation for more details.
Applications executed on the GAS server must use the UTF-8 encoding. Mobile front-ends will reject any attempt to display forms of an application using an encoding other than UTF-8.
Implementing the embedded mobile app
Create a small application to be deployed on the mobile device, which then starts the application(s) on an GAS server.
The server application is started from the embedded application through the runOnServer
front call. The
embedded mobile application can be a very simple MAIN / END MAIN
program, only
performing the "runOnServer
" front call.
MAIN
CALL ui.interface.frontcall("mobile","runOnServer",
["http://myappserver:6394/ua/r/myapp"],[])
END MAIN
When the remote application starts, the graphical user interface displays on the mobile device.
When the the called server-side application ends, the runOnServer
front call
returns, and control goes back to the initial application executing on the mobile device.
In development context, it is possible to execute the parent starter app on a server, display on
a mobile device with FGLSERVER set properly, and use the
runOnServer
front call. Because starting remote GAS applications is done with a
front call, this configuration mimics an embedded starter app running on the device.
Using the runOnServer front call
The application executed on the server-side is identified by the first parameter of the
runOnServer
front call. This application must be delivered by the Genero
Application Server. The parameter must contain an "ua/r
" URL syntax (the UA
protocol introduced with the GAS 3.00).
For example: http://myappserver:6394/ua/r/myapp
The URL may contain a query string, with parameters for the application to be executed by the GAS.
If needed, you can add a second argument to define a timeout as a number of seconds. The embedded application will wait for the remote application to start, until the timeout expired.
TRY/CATCH
block, to check if the execution of the server application was
successful:MAIN
TRY
CALL ui.interface.frontcall("mobile","runOnServer",
["http://myappserver:6394/ua/r/myapp"],[])
CATCH
ERROR err_get(status)
END TRY
END MAIN
Subsequent server-side application runs are allowed; the last active application will display on
the device. However, it is not possible to navigate between started applications. Therefore, an
application started with the runOnServer
front call must only use the RUN
instruction to start sub-programs.
RUN WITHOUT WAITING
is not supported.
Passing parameters to the server application
?Arg=value1&Arg=value1&...
notation:DEFINE params, base, complete_url STRING
LET params = "Arg=verbose&Arg=5677"
LET url = "http://myappserver:6394/ua/r/myapp"
LET complete_url = base || "?" || params
The remote program can retrieve the parameters with the arg_val()
built-in function.
runOnServer
front call.See the GAS documentation (AllowUrlParameters
attribute) about passing
parameters in the application URL.
IMPORT util
MAIN
DEFINE arr DYNAMIC ARRAY OF STRING, x INT
MENU "test"
COMMAND "runOnServer"
CALL arr.clear()
LET arr[1] = "first argument"
LET arr[2] = "second argument"
LET x = do_run("http://10.0.40.29:6394/ua/r/test1", 10, arr)
COMMAND "exit"
EXIT MENU
END MENU
END MAIN
FUNCTION do_run(url,timeout,params)
DEFINE url STRING,
timeout SMALLINT,
params DYNAMIC ARRAY OF STRING
DEFINE i, r INTEGER, tmp STRING
LET r = 0
LET tmp = url
FOR i=1 TO params.getLength()
LET tmp = tmp || IIF(i==1,"?","&") || "Arg=" || params[i]
END FOR
TRY
CALL ui.interface.frontcall("mobile","runOnServer",[tmp,timeout],[])
CATCH
ERROR err_get(status)
LET r = -1
END TRY
RETURN r
END FUNCTION
MAIN
MENU "Prog1"
COMMAND "arg1" MESSAGE "Arg 1 = ", arg_val(1)
COMMAND "arg2" MESSAGE "Arg 2 = ", arg_val(2)
COMMAND "arg3" MESSAGE "Arg 3 = ", arg_val(3)
COMMAND "Quit" EXIT MENU
END MENU
END MAIN
Sharing files between embedded and server app
If files need to be shared between the embedded application and the server application, the
application running on the GAS can only access the data-directory directory,
in the sandbox of the embedded application that executes the "runOnServer
"
front call.
This matters when using file handling APIs such as fgl_putfile()
and fgl_getfile()
or front
calls like takePhoto
and launchURL
.
The data-directory on the mobile device can be found with the feInfo/dataDirectory
front
call. In both the embedded app and the app running on the server, this front call will return
the same directory.
- Before starting the server application with a
runOnServer
front call, the embedded app must copy files to the data-directory. - While executing, the server application can retrieve files from the
data-directory with
fgl_getfile()
, and send its own files to the data-directory, withfgl_putfile()
. - When the server application terminates, the embedded app can read files the server application left in the data-directory.
RUN
instruction, make sure to not overwrite files written by other server
programs.In order to write code for the embedded app, that can be executed in development mode (running
on a server) and on the mobile device, you can adapt to the execution context: Make a simple file
copy when executing on the mobile device, or do an fgl_putfile()
call, when
running on the development server. Check the execution context with the
base.Application.isMobile()
method.
IMPORT os
...
CALL mobile_copy_to_data_dir("myfile.txt")
...
FUNCTION mobile_copy_to_data_dir(fn)
DEFINE fn, dd, dst STRING, r INT
CALL ui.interface.frontcall("standard","feInfo",["dataDirectory"],[dd])
-- Always use / as path sep for Android/iOS dirs.
LET dst = dd || "/" || os.Path.basename(fn)
IF base.Application.isMobile() THEN
-- Executing on device: make a simple copy to data-dir
LET r = os.Path.copy(fn, dst)
MESSAGE SFMT("COPY status = %1", r)
ELSE
-- Executing on dev server: make a file transfer to data-dir
CALL fgl_putfile(fn, dst)
END IF
END FUNCTION
We do not use the os.Path.join()
method here, because it
would add the path separator for the operating system where the application is executed. This would
not be a problem when executing on the mobile device or Unix-like platforms. However, when running
on a Windows® platform, the
os.Path.join()
method would join the directory and the file name with a backslash,
and the resulting path would not fit Android™ or iOS directory path specification for the data-directory.fgl_getfile()
function, to transfer a file
from the mobile device data-directory to the local server
disk:IMPORT os
...
CALL server_get_from_data_dir("myfile.txt", "/tmp/server_file.txt")
...
FUNCTION server_get_from_data_dir(fn, dst)
DEFINE fn, dst, dd, src STRING
CALL ui.interface.frontcall("standard","feInfo",["dataDirectory"],[dd])
-- Use / as path sep for Android/iOS dirs!
LET src = dd || "/" || fn
CALL fgl_getfile(src, dst)
END FUNCTION
fgl_putfile()
function, to copy
a file from the server application to the data-directory of the embedded
app:IMPORT os
...
CALL server_put_to_data_dir("/tmp/server_file.txt", "myfile.txt")
...
FUNCTION server_put_to_data_dir(src, fn)
DEFINE src, fn, dd, dst STRING
CALL ui.interface.frontcall("standard","feInfo",["dataDirectory"],[dd])
-- Use / as path sep for Android/iOS dirs!
LET dst = dd || "/" || fn
CALL fgl_putfile(src, dst)
END FUNCTION