Numeric data types
Informix®
Informix supports several data types to store numbers:
Informix data type | Description |
---|---|
SMALLINT |
16 bit signed integer |
INTEGER |
32 bit signed integer |
BIGINT |
64 bit signed integer |
INT8 |
64 bit signed integer (replaced by
BIGINT ) |
DECIMAL |
Equivalent to DECIMAL(16) |
DECIMAL(p) |
Floating-point decimal number (max precision is 32) |
DECIMAL(p,s) |
Fixed-point decimal number (max precision is 32) |
MONEY |
Equivalent to DECIMAL(16,2) |
MONEY(p) |
Equivalent to DECIMAL(p,2) (max precision is
32) |
MONEY(p,s) |
Equivalent to DECIMAL(p,s) (max precision is
32) |
REAL / SMALLFLOAT |
32-bit floating point decimal (C float) |
DOUBLE PRECISION / FLOAT[(n)] |
64-bit floating point decimal (C double) |
Netezza®
Netezza supports the following data types to store numbers:
Netezza data type | Description |
---|---|
BYTEINT |
8-bit value with the range -128 to 127 |
SMALLINT |
16 bit signed integer |
INTEGER |
32 bit signed integer |
BIGINT |
64 bit signed integer |
DECIMAL(p,s) |
Exact decimal number with p significant digits and s decimals (1<=p<=38) |
DECIMAL(p) |
Integer with precision p (1<=p<=38) |
DECIMAL |
Integer, same as NUMERIC(18,0) |
FLOAT(p) with 1 <= p <= 6 |
16 bit approx floating point (C float) |
FLOAT(p) with 7 <= p <= 15 |
32 bit approx floating point (C double) |
REAL |
Same as FLOAT(6) |
DOUBLE PRECISION |
Same as FLOAT(15) |
Solution
Use the following conversion rules to map Informix numeric types to Netezza numeric types:
Informix data type | Netezza equivalent |
---|---|
SMALLINT |
SMALLINT |
INTEGER |
INTEGER |
INT8 / BIGINT |
BIGINT |
DECIMAL(p,s) |
DECIMAL(p,s) |
DECIMAL(p) |
DECIMAL(p*2,p) |
DECIMAL |
DECIMAL(32,16) |
MONEY(p,s) |
DECIMAL(p,s) |
MONEY(p) |
DECIMAL(p,2) |
MONEY |
DECIMAL(16,2) |
SMALLFLOAT |
REAL |
FLOAT[(n)] |
FLOAT[(n)] (DOUBLE) |
There is no Netezza equivalent for the Informix DECIMAL(p)
floating point decimal (i.e. without
a scale). If your application uses such data types, you must review the database schema in order to
use Netezza compatible types.
To workaround the Netezza limitation, the NTZ database
drivers converts DECIMAL(p)
types to a DECIMAL( 2*p, p )
, to store
all possible numbers that an Informix
DECIMAL(p)
can store. However, the original Informix precision cannot exceed 19, since the Netezza maximum DECIMAL
precision is 38(2*19)
. If the
original precision is bigger than 19, a CREATE TABLE
statement executed from a
Genero program will fail with an SQL error.
dbi.database.dsname.ifxemul.datatype.smallint = { true | false }
dbi.database.dsname.ifxemul.datatype.integer = { true | false }
dbi.database.dsname.ifxemul.datatype.bigint = { true | false }
dbi.database.dsname.ifxemul.datatype.int8 = { true | false }
dbi.database.dsname.ifxemul.datatype.decimal = { true | false }
dbi.database.dsname.ifxemul.datatype.money = { true | false }
dbi.database.dsname.ifxemul.datatype.float = { true | false }
dbi.database.dsname.ifxemul.datatype.smallfloat = { true | false }
For more details see IBM Informix emulation parameters in FGLPROFILE.