ON CHANGE block
The ON CHANGE
block can be used to detect that a field changed
by user input. The ON CHANGE
block is executed if the value has changed since the
field got the focus and if the modification flag is set.
The ON CHANGE
block can be used in INPUT
, INPUT
ARRAY
and CONSTRUCT
dialogs.
For editable fields defined as EDIT
, TEXTEDIT
or BUTTONEDIT
, the ON CHANGE
block is executed
when leaving a field, if the value of the specified field has changed since the
field got the focus and if the modification flag is set for the field. You
leave the field when you validate the dialog, when you move to another field, or
when you move to another row in an INPUT ARRAY
. However, if the
text edit field is defined with the COMPLETER
attribute to enable
autocompletion, the ON CHANGE
trigger will be fired after a short
period of time, when the user has typed characters in.
For editable fields defined as CHECKBOX
,
COMBOBOX
, DATEEDIT
,
DATETIMEEDIT
, TIMEEDIT
,
RADIOGROUP
, SPINEDIT
,
SLIDER
or URL-based WEBCOMPONENT
(when the
COMPONENTTYPE
attribute is not used), the ON
CHANGE
block is invoked immediately when the user changes the value
with the widget edition feature. For example, when toggling the state of a
CHECKBOX
, when selecting an item in a
COMBOBOX
list, or when choosing a date in the calendar of a
DATEEDIT
. Note that for such item types, when ON
CHANGE
is fired, the modification flag is always set.
ON CHANGE order_checked -- Defined as CHECKBOX
CALL setup_dialog(DIALOG)
ON CHANGE
block and AFTER FIELD
block are defined
for a field, the ON CHANGE
block is executed before the AFTER
FIELD
block.When changing the value of the current field by program in an ON
ACTION
block, the ON CHANGE
block will be executed when leaving the field
if the value is different from the reference value and if the modification flag is set (after
previous user input or when the touched flag has been changed by program).
In an INPUT
or INPUT ARRAY
, the field value change is related
to value of the variable bound to the field. In a CONSTRUCT
dialog, the field value
change is related to the input buffer / displayed value.
NEXT FIELD
instruction, the comparison value is reassigned as
if the user had left and reentered the field. Therefore, when using NEXT FIELD
in
ON CHANGE
block or in an ON ACTION
block, the ON
CHANGE
block will only be invoked again if the value is different from the reference value.
This prevents field validation in ON CHANGE
blocks; you must do validations in
AFTER FIELD
blocks and/or AFTER INPUT
blocks.